From 7a52a4c33fb633a6bf227daf31e4ab65a444032e Mon Sep 17 00:00:00 2001 From: =?UTF-8?q?Sl=C3=A1vek=20Banko?= Date: Sun, 16 Feb 2020 14:34:08 +0100 Subject: Fix units of current consumption value. MIME-Version: 1.0 Content-Type: text/plain; charset=UTF-8 Content-Transfer-Encoding: 8bit Previously it was not clear whether the units in tdehwlib are in Wh and W or Ah and A. Now the units are always Ah and A. Because power consumption is usually given in W, the value is converted from A to W. If it is less than 100 W, it is displayed as a decimal number. This is related to issue TDE/tdelibs#68. Signed-off-by: Slávek Banko (cherry picked from commit fa0e4e246ccb8f436598db4deee1777decfbc702) --- src/hardware_battery.h | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-) (limited to 'src/hardware_battery.h') diff --git a/src/hardware_battery.h b/src/hardware_battery.h index 8f9a268..36bf68c 100644 --- a/src/hardware_battery.h +++ b/src/hardware_battery.h @@ -162,7 +162,7 @@ private: * second) the currently reported charging/discharging rate. * \li a value >= 0 */ - int present_rate; + double present_rate; //! Expected minutes unitl fully discharged/charged /*! * This int tells the current estimate until the battery is fully @@ -262,8 +262,8 @@ public: int getState() const; //! estimates the remaining minutes until fully charged/discharged int getRemainingMinutes() const; - //! current charging/discharging rate - int getPresentRate() const; + //! current charging/discharging rate + double getPresentRate() const; //! maximum capacity of this battery by design int getDesignCapacity() const; //! current charging state as enum BAT_CHARG_STATE -- cgit v1.2.1